Accueil » Cooling » Active cooling » Active coolers (cooling) » LABO (coolers)
LABO (coolers)
CUSTOM-MADE active water coolers (or chillers) for laboratories and analysis centers
Key features:
- 100% custom-made adaptation!
- Compatible with water, glycol water, oil, emulsions...
- Wide range of power outputs and finishes
- Chillers specifically designed for "laboratories and analysis"
- DP variants (without tank) or D variants (without tank, without pump)
- Our Engineering department is here to help
In standard
- Available in versions compatible with water, glycol water, oil, emulsions, etc.
- Hermetic piston compressor
- Electronic thermostat with digital display
- Fan-cooled condenser
- Automatic expansion valve
- Insulated polyethylene tank
- Immersed stainless steel evaporator (LABO 02 to 07)
- All-stainless steel spiral plate evaporator (LABO 12 to 80) resistant to freezing
- Stainless steel centrifugal circulation pump (PEK LABO02-07)
- Flow control valve
- PVC and stainless steel hydraulic circulation piping
- Water level indicator and drain valve on the front panel
- On/Off switch on the front panel
- Water pressure gauge
- Sound insulation (low noise level)
- Aluminum base (except LABO 80)
- Textured RAL 7032 paint
- Complete documentation
- 18-month warranty (unless otherwise agreed)
Options and adaptations
- DP (tankless) or D (tankless, pumpless) variants
- Quick connectors
- PID control (+/- 0.2 °C accuracy and stability)
- Low-pressure pump (magnetic drive)
- Modbus interface (data transmission and control)
- 316 stainless steel casing
- Automatic bypass (pressure safety)
- Flow indicator
- Micro pack (installation accessory, vibration isolation)
- Casters
- Deionizing cartridge
- Heating element
- Special voltages/frequencies
- 4-20 mA interface
- 2 inputs/2 outputs
- Low temperatures (-20°C)
- Labix20 coolant
- RAL paint color other than standard
▶ TO BE SPECIFIED IN YOUR REQUEST
Technical specifications
| Examples of achievements | LABO 02 | LABO 07 | LABO 12 | LABO 20 | |
| Oil version available ? | YES | YES | YES | YES | |
| Power supply | Type | Single-phase | Single-phase | Single-phase | Single-phase |
| V-Hz | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | |
| Cooling power (+10°C water outlet, +32°C ambient) |
W |
200 | 700 | 1200 | 1600 |
| Cooling power (+10°C water outlet, +20°C ambient) |
W | 300 | 900 | 1500 | 2000 |
| Power consumption | W | 330 | 600 | 700 | 900 |
| Refrigerant | Type | R134a | R134a | R134a | R134a |
| Input current nominal / maxi |
A | 2.8 / 8.8 | 4 / 16 | 4.5 / 18 | 5 / 20 |
| Line protection | A | 4 | 4 | 6 | 6 |
| Electrical connection | mm² | nc | nc | nc | nc |
| Waterproof index | IP | nc | nc | nc | nc |
| Nominal air flow | m3/h | 255 | 390 | 570 | 900 |
| Available water flow mini / maxi |
l/mn | 1 / 9 | 1 / 9 | 1 / 9 | 3 / 41 |
| Available water pressure mini / maxi |
bar | 0.5 / 3.5 | 0.5 / 3.5 | 0.5 / 3.5 | 1 / 2.6 |
| Hydraulic connection | Type | nc | nc | nc | nc |
| Tank capacity | l | 5 | 8 | 8 | 8 |
| Operating temperature ambient mini / maxi |
°C | +10 / +40 | +10 / +40 | +10 / +40 | +10 / +40 |
| Regulation temperature range mini / maxi |
°C | +5 / +20 | +5 / +20 | +5 / +20 | +5 / +20 |
| Noise level | dB(A) | < 60 | < 60 | < 60 | < 60 |
| Dimensions |
H (mm) | 260 | 310 | 813 | 813 |
| L (mm) | 410 | 460 | 450 | 450 | |
| P (mm) | 410 | 620 | 450 | 450 | |
| Weights | kg | 26 | 45 | 60 | 90 |
| Non-contractual values / More information about air conditioning and cooling systems can be found on AFCE. | |||||
| Examples of achievements | LABO 30 | LABO 45 | LABO 45 T | LABO 80 T | |
| Oil version available ? | YES | YES | YES | YES | |
| Power supply | Type | Single-phase | Single-phase | Three-phase | Three-phase |
| V-Hz | 230-1-50 | 230-1-50 | 400-3-50 | 400-3-50 | |
| Cooling power (+10°C water outlet, +32°C ambient) |
W |
2400 | 5000 | 5000 | 9000 |
| Cooling power (+10°C water outlet, +20°C ambient) |
W | 3000 | 6000 | 6000 | 11000 |
| Power consumption | W | 1.4 | 2.5 | 2.65 | 3.9 |
| Refrigerant | Type | R134a | R407C | R407C | R407C |
| Input current nominal / maxi |
A | 6.5 / 31 | 12.5 / 76 | 6 / 42 | 8.2 / 60 |
| Line protection | A | 8 | 16 | 8 | 10 |
| Electrical connection | mm² | nc | nc | nc | nc |
| Waterproof index | IP | nc | nc | nc | nc |
| Nominal air flow | m3/h | 1500 | 2000 | 2000 | 4000 |
| Available water flow mini / maxi |
l/mn | 3 / 41 | 3 / 41 | 3 / 41 | 30 / 80 |
| Available water pressure mini / maxi |
bar | 1 / 2.6 | 1 / 2.6 | 1 / 2.6 | 2 / 2.9 |
| Hydraulic connection | Type | nc | nc | nc | nc |
| Tank capacity | l | 30 | 30 | 30 | 60 |
| Operating temperature ambient mini / maxi |
°C | +10 / +40 | +10 / +40 | +10 / +40 | +10 / +40 |
| Regulation temperature range mini / maxi |
°C | +5 / +20 | +5 / +20 | +5 / +20 | +5 / +25 |
| Noise level | dB(A) | < 60 | < 60 | < 60 | < 60 |
| Dimensions |
H (mm) | 966 | 1204 | 1204 | 1410 |
| L (mm) | 476 | 671 | 671 | 1050 | |
| P (mm) | 595 | 759 | 759 | 840 | |
| Weights | kg | 120 | 145 | 145 | 260 |
| Non-contractual values / More information about air conditioning and cooling systems can be found on AFCE. | |||||
Diagrams
More about LABO coolers
LABO water coolers (chillers) are regularly used in the cooling of laboratory processes, samples, lasers, microscopes…
Quick to configure and manufacture, we offer a wide range of options.
For example:
- The choice of pumps (centrifugal, peripheral, etc.) allows for pressure and flow rate adjustments to suit the process (from 0.5 to 6 bar);
- or, a stainless steel design to handle any type of fluid (demineralized water, deionized water, etc.).
Specifically designed for user comfort, LABO water coolers offer a reduced noise level, allowing them to be integrated into quiet working environments.
> Contact our specialists now to meet your coolers and air conditioner needs.