Accueil » Air conditioning » Active air conditioners » Side-mounted active air conditioners » CLC (air conditioners)
CLC (air conditioners)
CUSTOM-MADE side mounted air conditioners
Key features:
- 100% custom-made adaptation!
- Wide range of cooling powers (2000 to 21000 W... or more!)
- Numerous options and possible configurations
- Our Engineering department is here to help
En standard
- Side mounting, external to the cabinet
- Lifting ring
- Color RAL 7032 or 7035
- Main models available: CLC20, CLC40, CLC60, CLC80, CLC100, CLC150, CLC250
- Complete documentation
- 18-month warranty (unless otherwise agree)
Sur mesure
- Side mounting, inside the cabinet
- EXTT version (outdoor installation)
- Mechanical or electronic thermostat
- Heating element
- Fan speed variation on the condenser
- Internal anti-corrosion treatment and stainless steel casing
- Custom control/command
- Redundancy of multiple units
- RAL paint different from the standard
Technical specifications
| Examples of achievements | CLC 20 CAI | CLC 20 TAI | CLC 40 CAI | CLC 40 TAI | |
| EXTT* version available? | YES | YES | YES | YES | |
| Power supply | Type | Single-phase | Three-phase | Single-phase | Three-phase |
| V-Hz | 230-1-50/60 | 400-3-50 | 230-1-50 | 400-3-50 | |
| Cooling power A35A35 (+35°C inside cabinet, +35°C ambient) |
W | 2000 | 2000 | 3000 | 3000 |
| Power consumption A35A35 (+35°C inside cabinet, +35°C ambient) |
W | 1148 [1188**] | 1025 | 15553 | 1517 |
| Refrigerant | Type | R513A | R513A | R513A | R513A |
| Input current nominal / maxi |
A | 5.47 / 21.8 [5.75 / 21.8**] |
3.1 / 16 | 7.4 / 31 | 3.5 / 13 |
| Line protection | A | 8 | 4 | 8 | 4 |
| Electrical connection | Type | nc | nc | nc | nc |
| Waterproof index indoor / outdoor |
IP | 56 / 54 | 56 / 54 | 56 / 54 | 56 / 54 |
| Nominal air flow | m3/h | 600 | 600 | 800 | 800 |
| Operating temperature ambient mini / maxi |
°C | +10 / +55 | +10 / +55 | +10 / +55 | +10 / +55 |
| Regulation temperature range mini / maxi |
°C | nc / nc | nc / nc | nc / nc | nc / nc |
| Noise level | dB(A) | 70 | 70 | 70 | 70 |
| Dimensions |
H (mm) | 1006 | 1006 | 1210 | 1210 |
| L (mm) | 402 | 402 | 508 | 508 | |
| P (mm) | 240 | 240 | 310 | 310 | |
| Weights | kg | 55 | 55 | 86 | 86 |
| * EXTT version: device configured for outdoor installation ** Values at 60 Hz Non-contractual values / More information about air conditioning and cooling systems can be found on AFCE. |
|||||
| Examples of achievements | CLC 60 TAI | CLC 80 TAI | CLC 100 TAI | CLC 150 TAI | CLC 250 TAI | |
| EXTT* version available? | YES | YES | YES | YES | YES | |
| Power supply | Type | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase |
| V-Hz | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | |
| Cooling power A35A35 (+35°C inside cabinet, +35°C ambient) |
W | 5800 | 7600 | 9400 | 12000 | 20500** |
| Cooling power A35A50 (+35°C inside cabinet, +50°C ambient) |
W | 4350 | 5700 | 7000 | nc | nc |
| Power consumption A35A35 (+35°C inside cabinet, +35°C ambient) |
W | 2340 | 3300 | 3650 | 4620 | 11040** |
| Refrigerant | Type | R513A | R513A | R513A | R513A | R513A |
| Input current nominal / maxi |
A | 6 / 21.7 | 8.1 / 31 | 9.1 / 31 | 9.42 / 136 | 23.2 / 80 |
| Line protection | A | 8 | 16 | 20 | 12 | 32 |
| Electrical connection | Type | Sur bornier | Sur bornier | Sur bornier | nc | nc |
| Waterproof index indoor / outdoor |
IP | 54 / 34 | 54 / 34 | 54 / 34 | 56 / 54 | nc / nc |
| Nominal air flow | m3/h | nc | nc | nc | 2200 | nc |
| Operating temperature ambient mini / maxi |
°C | +20 / +50 | +20 / +50 | +20 / +45 | +20 / +45 | +10 / +60 |
| Regulation temperature range mini / maxi |
°C | nc / nc | nc / nc | nc / nc | +25 / +45 | +25 / +45 |
| Noise level | dB(A) | 72 | 75 | 77 | 70 | nc |
| Dimensions |
H (mm) | 2000 | 2000 | 2000 | 2000 | 2350 |
| L (mm) | 600 | 800 | 1200 | 1200 | 1500 | |
| P (mm) | 387 | 387 | 387 | 400 | 1074 | |
| Weights | kg | 150 | 160 | 180 | 230 | nc |
| * EXTT version: device configured for outdoor installation ** Under measurement conditions: +30°C internal cabinet, +60°C ambient, 30% humidity Non-contractual values / More information about air conditioning and cooling systems can be found on AFCE. |
||||||
Advantage of our CLC air conditioners: custom adaptation
Our key strength in the CLC range of custom-made side-mounted air conditioners?
Our ability to design and manufacture fully customized air conditioners, perfectly suited to the specific requirements of industrial environments.
Unlike standardized solutions, which are often limited in the face of specific technical constraints (extreme temperatures, corrosive atmospheres, confined spaces or reinforced filtration needs), EURODIFROID develops equipment designed from the outset to meet the realities of the field.
This personalized approach makes it possible to optimize the thermal performance, reliability and durability of the installations, while controlling operating costs.
Thanks to our technical expertise and end-to-end support (from study to manufacturing), we guarantee our clients a solution perfectly integrated into their industrial process, thus improving business continuity and the safety of sensitive equipment.
> Consult our experts now for advice and a quote on the best air conditioners for your needs!