CIT (air conditioners)

CUSTOM-MADE active air conditioners for racks and technical bays

Key features:

  • 100% custom-made adaptation!
  • "Split" principle: 1 outdoor unit + 1 indoor unit
  • Optimized airflow
  • Our Engineering department is here to help
Request a quote

In standard

Indoor unit

  • Electric thermostat with digital display
  • Refrigerant inlet/outlet on the top of the indoor unit
  • Liquid reservoir
  • Isolation refrigerant valves
  • Specific adapter frame for rear air intake/front air outlet
  • Color RAL 7035

Outdoor unit

  • Ventilation pressure switch and condensing pressure regulator
  • IP55 electrical junction box for the outdoor unit
  • Refrigerant isolation valves
  • Crankcase heater
  • RAL 7032 color

 

  • Complete documentation
  • 18-month warranty (unless otherwise agreed)

Options and adaptations

Indoor unit

  • Mechanical thermostat
  • 24 VAC fans
  • RAL paint color different from standard

Outdoor unit

  • Refrigeration pressure gauges
  • BLYGOLD coating on the condenser coil
  • RAL paint color other than standard

▶ TO BE SPECIFIED IN YOUR REQUEST

Technical specifications


Examples of achievements CIT 15 AAI
CIT 15 TAI CIT 30 AAI CIT 30 TAI CIT 50 AAI CIT 50 TAI
Power supply Type Single-phase Three-phase Single-phase Three-phase Single-phase Three-phase
V-Hz 230-1-50 400-3-50 230-1-50 400-3-50 230-1-50 400-3-50
Cooling power
(+25°C in cabinet, +32°C ambient)
W 1500 1500 3000 3000 4500 4500
Power consumption* W 1103 / 65 1260 / 65 2419 / 85 2419 / 85 2457 / 140 2616 / 140
Refrigerant Type R134a R134a R134a R134a R134a R134a
Input current*
nominal
A 6.3 / 0.3 2.0 / 0.3 8.7 / 0.5 8.7 / 0.5 12.2 / 0.6 4.7 / 0.6
Line protection A 10 4 12 4 16 6
Electrical connection Type 7G2.5 7G2.5 7G2.5 7G2.5 7G2.5 7G2.5
Electrical connection IP 54 54 54 54 54 54
Nominal air flow m3/h 500 500 900 900 1200 1200
Operating temperature
ambient mini / maxi
°C +10 / +40 +10 / +40 +5 / +40 +5 / +40 +5 / +40 +5 / +40
Noise level dB(A) <69 <69 65 65 68 68
Dimensions
indoor unit / outdoor unit
H (mm) 342 / 600 342 / 600 630 / 1000 630 / 1000 630 / 1200 630 / 1200
L (mm) 550 / 300 550 / 300 640 / 400 640 / 400 640 /  650 640 / 650
P (mm) 697 / 160 697 / 160 650 / 200 650 / 200 650 / 250 650 / 250
Weights
indoor unit / outdoor unit
kg 47 / 15 47 / 15 80 / 29 80 / 29 80 / 34 80 / 34
* Outdoor unit / Indoor unit
Non-contractual values / More information about air conditioning and cooling systems can be found on AFCE.

 

 


Diagrams

More information about the CIT air conditioners

Designed with a “split” operation (indoor unit and outdoor unit), the CIT range of active air conditioners was designed to cool small computer bays, or technical racks, in confined environments.

It therefore regularly finds its “typical application” in a server installed in a confined space or in a small, un-air-conditioned room housing an electrical cabinet requiring reliable temperature control.

You will therefore find all the advantages of this type of mounting for your technical rack or bay :

  • Compact size of the indoor unit;
  • No internal heat transfer;
  • Complete flexibility in outdoor unit installation;
  • Simple and easy connection between indoor and outdoor units.

In addition, the CIT range of air conditioners allows for optimization of airflow inside the bay by a cold air intake at the back of the cabinet and a cold air blowing at the front (see below).

Going further: examples of drilling and airflow (rack/bay air conditioners)


Our CIT rack, bay or cabinet air conditioners are all installed in the same way:

  • Drilling and cutting of the electrical cabinet
  • Positioning the indoor unit on the electrical cabinet
    (front/rear cutouts then fixing to the adapter frame)
  • Positioning the outdoor unit (maximum length: 25 linear meters)
  • Refrigerant connection via ¾” copper piping
  • Electrical connection via a single cable (7G2.5)
  • Vaping and charging with R134a refrigerant (1.9 kg)
  • Starting the system: cold air then circulates from top to bottom in the cabinet

And, on our CIT 30 or CIT 50 air conditioners, we also offer you the possibility of mounting with “back to front” air circulation in the cabinet (see diagram aside).

Our teams are available to advise you on the most effective product/assembly combination, and have all the preparation documents you may need at your disposal.

> Do you have a question about your installations and the most suitable air conditioners? Contact us.

 

Discover similar air conditioning solutions


KCN air conditioners for racks and bays
Rack/bay active air conditioners
KCN (air conditioners)
Read more
Active rack/bay CIT air conditioners, split design
Rack/bay active air conditioners
CIT (air conditioners)
Read more
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.